Cable & Wire
Cable & Wire Suppliers in Ahmedabad Gujarat1. AYY/YY- 1 core
![]() |
![]() |
1.1 kV (A.C) & 1.5 kV (D.C ) to Earth
1 cores AL / CU conductor, PVC insulated, unarmoured cables as per IS 1554 Part – 1.
Conductor : AL up to 10 Sq. mm conductor are solid Cl.1 as per IS 8130. And above 10 Sq. mm conductor are stranded round or compact Cl. 2 as per IS 8130
In CU 4 & 6 Sq. mm conductor are solid Cl.1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm & above stranded round or stranded compact Cl. 2 as per IS 8130
Insulation : PVC Type – A, as per IS 5831. (Option : HR PVC Type – C, as per IS 5831)
Core Color : Red or yellow or blue or black or natural
Outer Sheath : PVC Type ST-1 as per IS 5831. (Option : PVC Type – ST 2 as per IS 5831 / FR Type / FRLS Type )
Cable Color : Black (Options : Any other color as per requirement)
Cable Design Parameters
While ordering, in addition to the part number the following details shall also be advised:
Conductor Type (Aluminium or Copper) and class of conductor (Cl. 1 or 2).
Insulation Type – PVC Type A / C.
Sheath Type – PVC Type ST-1 / FR / FRLS; PVC Type ST-2 / FR / FRLS.
Colour from above technical details.
2. AYY/YY-2 CORE
![]() |
![]() |
3. AYY/YY – 3 CORE
![]() |
![]() |
4. AYY/YY – 3.5 CORE
![]() |
![]() |
5. Ratnaflex multicore
![]() |
![]() |
These cables are designed for residential and commercial infrastructure. They serve as the connecting medium in power and control panels, cabinets & switchgears. They can also used for the purposes such as stationary and static appliances, motors and for other single phase connections.
Ratnaflex -M: PVC insulated & sheathed multicore cables suitable for all general purpose wirings for max. operating temperature of 70oC.
Ratnaflex -M HR: HR PVC insulated & sheathed multicore cales suitable for higher operating temperature of 70oC.
Ratnaflex -M FR: Flame Retardant (FR) multicore cable enhances safety and are suitable for max. operating temperature 70oC.
Ratnaflex -M HRFR: Heat Resistant (HR) & Flame Retardant (FR) multicore cables are suitable for higher operating temperature up to 85oC with enhanced safety.
Ratnaflex -M FR-LSH: Flame Retardant Low Smoke Low Halogen (FR-LSH) cables are suitable for wiring in public places like schools, hospitals, theatres, etc.
Technical Data
Approvals : IS 694 marked, FIA/TAC
Conductor : Electrolytic grade annealed copper Class 5 as per IS 8130
Standard Cable Colour : Black, grey & white
Voltage Rating : Up to and including 1100V
Packing : Standard packing of 100 mtr. in coil. Longer length available on request
Variants Available
Product Type/Legends | Specifications | ||
RATNAFLEX-M | IS 694, IS 8130 Class 5, IS 5831 Type D for insulation & ST-3 & for sheathing | ||
RATNAFLEX-M HR | IS 694, IS 8130 Class 5, IS 5831 Type C for insulation & ST-2 for sheathing | ||
RATNAFLEX-M FR | IS 694, IS 8130 Class 5, IS 5831 Type D for insulation & ST-3 (FR) & for sheathing | ||
RATNAFLEX-M HR FR | IS 694, IS 8130 Class 5, IS 5831 Type C for insulation & ST-2 (FR) for sheathing | ||
RATNAFLEX-M FR-LSH | IS 694, IS 8130 Class 5, IS 5831 Type D for insulation & ST-3 (FR-LSH) for sheathing | ||
Please complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required. | Kindly complete the part numbers for these cables by adding the suffix (in place of ‘y’) for the product type required. | Kindly complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required. | |
06 – green-yellow earth core. We offer green/yellow earth core as our standard product. 00 – without green-yellow earth core (available on request). | 1 – PVC 70°C, 2 – PVC FR 70°C, 3 – PVC HR 85°C, 4 – PVC HR 85°C + FR, 5 – PVC FR-LSH. | 1 – black, 4 – grey, 5 – white. | |
6. H03/H05VVH2-F & H03/H05VV-F
![]() |
![]() |
Application
For use in connections of household appliances, plant and machinery, wiring purposes and for manufacturing cords.
Standard
BS EN 50525-2-11, DIN EN 50525-2-11; VDE 0285-525-2-11, EN 50525-2-11.
Technical Data
Nominal Voltage : 300/500V (H05VV-F & H05VVH2-F); 300/300V (H03VV-F & H03VVH2-F)
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -5°C to +70°C. Fixed Installation : -30°C to +70°C
Minimum Bending Radius: Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
Test Voltage : 4000V
Breakdown Voltage : Min. 8000V
Cable Construction
Bare copper, fine wire conductors, as per EN 60228 Cl.5. PVC core insulation TI2, to EN 50363-3.
Harmonised core colour to HD 308 (Refer Appendix Table No. 1-1). Cores stranded in layers with optimal lay-length.
PVC outer sheath TM2, to EN 50363-4.1.
H05VV-F is also available in oil resistant variant as H05VV5-F.
The outer sheath provided here is of special PVC, TM5 to BS EN 50363-4.1.
Properties
PVC self-extinguishing and flame retardant according to EN 60332-1-2.
Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required:
1 – black (RAL 9005), 3 – grey (RAL 7001), 5 – white (RAL 9010). For Oil Resistant sheath kindly add ‘OR’ after the part nos.
7. H03 / H05V2V2H2-F & H03 / H05V2V2-F
![]() |
![]() |
Application
For use in connections of household appliances and internal wiring purposes with high ambient temperatures and humid spaces
Standard
BS EN 50525-2-11.
Technical Data
Nominal Voltage : 300 / 500V (H05V2V2H2-F / H05V2V2-F); 300 / 300V (H03V2V2H2-F / H03V2V2-F)
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range :
Flexing -5°C to +90°C
Fixed Installation -30°C to +90°C
Fixed Installation 5 x cable ø
Minimum Bending Radius : Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
Test Voltage : 4000V
Breakdown Voltage : Min. 8000V
Cable Construction
Bare copper, fine wire conductors, as per EN 60228 Cl.5.
PVC core insulation TI3, to EN 50363-3.
Harmonised core colour to HD 308 (Refer Appendix Table No. 1-1).
Cores stranded in layers with optimal lay-length.
PVC outer sheath TM3, to EN 50363-4.1
Properties
PVC self-extinguishing and flame retardant according to EN 60332-1-2.
Cable Design Parameters
Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required,
1 – black (RAL 9005), 2 – grey (RAL 7001), 3 – white (RAL 9010).
8. FR FLAME RETARDANT
Single core multi-stranded copper conductor, FR PVC insulated wires with excellent flame retardant properties.
9. FRLS-FLAME REDUNDANT LOW SMOKE LOW HALOGEN
Single core multi-standard copper conductor, FRLS PVC insulated wire with excellent flame retardant, low smoke, and Low halogen properties.
10. FRZH-FLAME REDUNDANT ZERO HALOGEN
Single core multistandard copper conductor, FRZH insulated wire with excellent flame retardant low smoke properties having Rohs compliances zero halogen
- We keep ready stock in many varieties of cables and wires.
Extremely use
1. Industries
2. Residents and commercial projects
We Provide:
- LT XLPE & PVC Power Cables
- LT XLPE & PVC Control Cables
- MV / HT & EHV Cables
- MV / LV Aerial Bunched Cables
- Telecommunication Cables & Wires
- Building Wires – FR / FRLSH / FRZH
- Single & Multi core Copper Flexible Cables
- Railway Sigmalling Cables
- Submersible Flat & Round Cables
- Instrumentation Cables & Wires
- Rubber & Trailing Cables
- Solar AC / DC Cables & Wires
- Fire Survival / FRLS / Zero Halogen Cables
- Screened & Shielded Cables & Wires
- Lan & Computer Cables
- Coaxial Cables
- Auto / Welding Cables
- Audio / Speaker Wires
- Lead Sheated Cables
- Speciality Cables