RR Kabel distributor in Ahmedabad, cables and wire suppliers Changodar
9510861701 , 9824686570 bijleebajaar@gmail.com

Cable & Wire

Cable & Wire Suppliers in Ahmedabad Gujarat

 1.   AYY/YY- 1 core

1.1 kV (A.C) & 1.5 kV (D.C ) to Earth
1 cores AL / CU conductor, PVC insulated, unarmoured cables as per IS 1554 Part – 1.
Conductor : AL up to 10 Sq. mm conductor are solid Cl.1 as per IS 8130. And above 10 Sq. mm conductor are stranded round or compact Cl. 2 as per IS 8130
In CU 4 & 6 Sq. mm conductor are solid Cl.1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm & above stranded round or stranded compact Cl. 2 as per IS 8130
Insulation : PVC Type – A, as per IS 5831. (Option : HR PVC Type – C, as per IS 5831)
Core Color : Red or yellow or blue or black or natural
Outer Sheath : PVC Type ST-1 as per IS 5831. (Option : PVC Type – ST 2 as per IS 5831 / FR Type / FRLS Type )
Cable Color : Black (Options : Any other color as per requirement)

Cable Design Parameters

While ordering, in addition to the part number the following details shall also be advised:
Conductor Type (Aluminium or Copper) and class of conductor (Cl. 1 or 2).
Insulation Type – PVC Type A / C.
Sheath Type – PVC Type ST-1 / FR / FRLS; PVC Type ST-2 / FR / FRLS.
Colour from above technical details.

2.   AYY/YY-2 CORE

 

 

 

 3.   AYY/YY – 3 CORE

 4.   AYY/YY – 3.5 CORE

 

 

5.   Ratnaflex multicore

These cables are designed for residential and commercial infrastructure. They serve as the connecting medium in power and control panels, cabinets & switchgears. They can also used for the purposes such as stationary and static appliances, motors and for other single phase connections.
Ratnaflex -M: PVC insulated & sheathed multicore cables suitable for all general purpose wirings for max. operating temperature of 70oC.
Ratnaflex -M HR: HR PVC insulated & sheathed multicore cales suitable for higher operating temperature of 70oC.
Ratnaflex -M FR: Flame Retardant (FR) multicore cable enhances safety and are suitable for max. operating temperature 70oC.
Ratnaflex -M HRFR: Heat Resistant (HR) & Flame Retardant (FR) multicore cables are suitable for higher operating temperature up to 85oC with enhanced safety.
Ratnaflex -M FR-LSH: Flame Retardant Low Smoke Low Halogen (FR-LSH) cables are suitable for wiring in public places like schools, hospitals, theatres, etc.

Technical Data

Approvals : IS 694 marked, FIA/TAC
Conductor : Electrolytic grade annealed copper Class 5 as per IS 8130
Standard Cable Colour : Black, grey & white
Voltage Rating : Up to and including 1100V
Packing : Standard packing of 100 mtr. in coil. Longer length available on request

Variants Available

Product Type/Legends Specifications
RATNAFLEX-M IS 694, IS 8130 Class 5, IS 5831 Type D for insulation & ST-3 & for sheathing
RATNAFLEX-M HR IS 694, IS 8130 Class 5, IS 5831 Type C for insulation & ST-2 for sheathing
RATNAFLEX-M FR IS 694, IS 8130 Class 5, IS 5831 Type D for insulation & ST-3 (FR) & for sheathing
RATNAFLEX-M HR FR IS 694, IS 8130 Class 5, IS 5831 Type C for insulation & ST-2 (FR) for sheathing
RATNAFLEX-M FR-LSH IS 694, IS 8130 Class 5, IS 5831 Type D for insulation & ST-3 (FR-LSH) for sheathing
Please complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required. Kindly complete the part numbers for these cables by adding the suffix (in place of ‘y’) for the product type required. Kindly complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required.
06 – green-yellow earth core. We offer green/yellow earth core as our standard product. 00 – without green-yellow earth core (available on request). 1 – PVC 70°C, 2 – PVC FR 70°C, 3 – PVC HR 85°C, 4 – PVC HR 85°C + FR, 5 – PVC FR-LSH. 1 – black, 4 – grey, 5 – white.

 6.   H03/H05VVH2-F & H03/H05VV-F

Application

For use in connections of household appliances, plant and machinery, wiring purposes and for manufacturing cords.

Standard

BS EN 50525-2-11, DIN EN 50525-2-11; VDE 0285-525-2-11, EN 50525-2-11.

Technical Data

Nominal Voltage : 300/500V (H05VV-F & H05VVH2-F); 300/300V (H03VV-F & H03VVH2-F)
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -5°C to +70°C. Fixed Installation : -30°C to +70°C
Minimum Bending Radius: Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
Test Voltage : 4000V
Breakdown Voltage : Min. 8000V

Cable Construction

Bare copper, fine wire conductors, as per EN 60228 Cl.5. PVC core insulation TI2, to EN 50363-3.
Harmonised core colour to HD 308 (Refer Appendix Table No. 1-1). Cores stranded in layers with optimal lay-length.
PVC outer sheath TM2, to EN 50363-4.1.

H05VV-F is also available in oil resistant variant as H05VV5-F.
The outer sheath provided here is of special PVC, TM5 to BS EN 50363-4.1.

Properties

PVC self-extinguishing and flame retardant according to EN 60332-1-2.
Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required:
1 – black (RAL 9005), 3 – grey (RAL 7001), 5 – white (RAL 9010). For Oil Resistant sheath kindly add ‘OR’ after the part nos.

 

7.   H03 / H05V2V2H2-F & H03 / H05V2V2-F

Application

For use in connections of household appliances and internal wiring purposes with high ambient temperatures and humid spaces

Standard

BS EN 50525-2-11.

Technical Data

Nominal Voltage : 300 / 500V (H05V2V2H2-F / H05V2V2-F); 300 / 300V (H03V2V2H2-F / H03V2V2-F)
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range :
Flexing -5°C to +90°C
Fixed Installation -30°C to +90°C
Fixed Installation 5 x cable ø
Minimum Bending Radius : Flexing 7.5 x cable ø; Fixed installation 4 x cable ø
Test Voltage : 4000V
Breakdown Voltage : Min. 8000V

Cable Construction

Bare copper, fine wire conductors, as per EN 60228 Cl.5.
PVC core insulation TI3, to EN 50363-3.
Harmonised core colour to HD 308 (Refer Appendix Table No. 1-1).
Cores stranded in layers with optimal lay-length.
PVC outer sheath TM3, to EN 50363-4.1

Properties

PVC self-extinguishing and flame retardant according to EN 60332-1-2.

Cable Design Parameters

Please complete the part numbers for these cables by adding the suffix (in place of ‘z’) for the sheath colour required,
1 – black (RAL 9005), 2 – grey (RAL 7001), 3 – white (RAL 9010).

8.    FR FLAME RETARDANT

Single core multi-stranded copper conductor, FR PVC insulated wires with excellent flame retardant properties.

9.    FRLS-FLAME REDUNDANT LOW SMOKE LOW HALOGEN

Single core multi-standard copper conductor, FRLS PVC insulated wire with excellent flame retardant, low smoke, and Low halogen properties.

10.  FRZH-FLAME REDUNDANT ZERO HALOGEN

Single core multistandard copper conductor, FRZH insulated wire with excellent flame retardant low smoke properties having Rohs compliances zero halogen

 

  • We keep ready stock in many varieties of cables and wires.

Extremely use
1. Industries
2. Residents and commercial projects

We Provide:

  • LT XLPE & PVC Power Cables
  • LT XLPE & PVC Control Cables
  • MV / HT & EHV Cables
  • MV / LV Aerial Bunched Cables
  • Telecommunication Cables & Wires
  • Building Wires – FR / FRLSH / FRZH
  • Single & Multi core Copper Flexible Cables
  • Railway Sigmalling Cables
  • Submersible Flat & Round Cables
  • Instrumentation Cables & Wires
  • Rubber & Trailing Cables
  • Solar AC / DC Cables & Wires
  • Fire Survival / FRLS / Zero Halogen Cables
  • Screened & Shielded Cables & Wires
  • Lan & Computer Cables
  • Coaxial Cables
  • Auto / Welding Cables
  • Audio / Speaker Wires
  • Lead Sheated Cables
  • Speciality Cables